Acu-rite 100S Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Acu-rite 100S. ACU-RITE 100S User Manual [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - 100S READOUTS

100S READOUTSFOR MILLING APPLICATIONSREFERENCE MANUAL

Strona 2 - TABLE OF CONTENTS

100S Reference Manual7SETUPLinear Error CompensationWith 100S, you can compensate for machine tool wear. If you know thelinear error compensation (LEC

Strona 3

8100S Reference ManualSETUP( S - MMLEC =)x 1,000,000S = Standard lengthM = Measured length• In the DRO mode.• Place a standard of known length on th

Strona 4 - Overview

9100S Reference ManualSETUPScale ResolutionTo ensure accurate readings, the scale resolution shown for each axismust correspond with the resolution of

Strona 5 - Preparation

10100S Reference ManualSETUP• Move to the “Count Direction” display in the Setup mode. (Press SETUP and then the ENTER key until “Ct dir” appears). •

Strona 6 - Installing the Scales

100S Reference Manual11SETUPTesting the ScalesFollow these steps to confirm that the scale has been installed properly.The Counting Test will confirm

Strona 7 - Display Saver

12100S Reference ManualOPERATIONReference Mark EvaluationENC 125 encoders contain internal reference marks, approximately 4"apart along the lengt

Strona 8 - Parameter Setup

13100S Reference ManualOPERATION100S allows you to measure both absolute and incremental dimensions.A dimension measured from the point you define as

Strona 9 - Display Resolution

OPERATION14100S Reference Manual• Using the ABS/INCR key, select the absolute (ABS) mode. Also check that the proper measurement (inch or mm) is selec

Strona 10 - Linear Error Compensation

15100S Reference ManualOPERATIONHere’s how you would drill the holes using absolute dimensions. Notice that all of the dimensions are measured from th

Strona 11 - ABS/INCR key)

100S Reference ManualOPERATION16As described earlier, incremental dimensions are measured from thecurrent tool position to the next. If the tool is cu

Strona 12 - Scale Resolution

Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Preparation . . . . . . . . . . . . . . . . . . .

Strona 13 - Position Recall

100S Reference Manual17OPERATIONExample: Incremental DimensionsLet’s say that your print looks like this:Hole 1 is an absolute dimension (measured fro

Strona 14 - Testing the Scales

100S Reference Manual18OPERATION1. Press the key (X, Y, or Z) for the axis you want to preset.100S will automatically switch to the incremental mode.2

Strona 15 - OPERATION

100S Reference Manual19OPERATIONExample: Incremental & Absolute Position PresetsHole 1 is an absolute dimension because it’s measured from datum.

Strona 16

20OPERATION100S Reference ManualCenterlineWith 100S, you can find the centerline (midpoint) between any twopositions on your part. You can establish c

Strona 17

100S Reference Manual21OPERATIONExample: Setting the Datum on a CenterlineHere’s how you would establish the datum onthe centerline of the part shown:

Strona 18

100S Reference Manual22OPERATIONLocating Centerline Using Incremental Dimensions1. Press the ABS/INCR key to select the incremental display mode.2. Mo

Strona 19 - Incremental Dimensions

100S Reference Manual23OPERATION4. Press the X key. Using the keypad, define the center point of the bolthole pattern on the X-axis. Use a decimal poi

Strona 20

100S Reference Manual24OPERATION6. Press the Y key. Enter the bolthole pattern’s center point on the Y-axis. Use a decimal point and minus (-) sign if

Strona 21

100S Reference Manual25OPERATIONRunning a Bolthole Pattern• Press the BOLT USE key. "HOLE" will appear on the X-axis display. The number of

Strona 22

100S Reference Manual26TROUBLESHOOTINGTroubleshooting IntroductionRefer to this troubleshooting guide whenever you have questions orconcerns about the

Strona 23 - Centerline

100S Reference ManualTABLE OF CONTENTSiiIncremental Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Example: Incremen

Strona 24

100S Reference Manual27RecommendedCorrective ActionDecimal pointscrolls acrossdisplayPress any key or move thetable to return to the previ-ous screen.

Strona 25

28TROUBLESHOOTING100S Reference ManualKeys notworking properlyError mes-sages (E2-E58) appearCauses varyInvalid keypressSymptomRecommendedCorrective A

Strona 26 - Bolthole Patterns

100S Reference Manual29TROUBLESHOOTINGScale counts,but not correctlyCheck that the scale cableis securely connected tothe readout.Loose cableCheck tha

Strona 27

100S Reference Manual30TROUBLESHOOTINGImproper procedure Press the ENTER key aftereach value is entered into aSetup screen. If you pressanother key in

Strona 28

100S Reference Manual31TROUBLESHOOTINGA ROM memory error has occurred. Press the CLEARkey to acknowledge the error. If the system does notoperate prop

Strona 29 - Troubleshooting Introduction

100S Reference ManualTROUBLESHOOTING32Error Messages (Keypad Test)The messages below indicate that a problem was found during the key-pad test at star

Strona 30

REFERENCE33CharacteristicSpecificationOperating conditions0° to 40°C (32° to 104°F)25% to 85% relative humidity (non-condensing)Storage conditions-40°

Strona 31

100S Reference ManualREFERENCE34Factory Default SettingsDisplay ResolutionLinear ErrorCompensationScale ResolutionCount DirectionBolt CircleDisplay Un

Strona 32

100S Reference ManualREFERENCE35KeypadHere’s an overview of the 100Skeypad. Each key’s function isdescribed below.ABS/INCRUsed to switch between absol

Strona 33

100S Reference ManualREFERENCE36±Changes the sign of the entered value from posi-tive(+) to negative(-) or vise versa. Numbers arepositive unless a (-

Strona 34 - Error Messages (General)

1100S Reference ManualGENERALOverviewThis manual will guide you through the installation, setup, and opera-tion of the 100S system. Use it to get you

Strona 35 - Error Messages (Keypad Test)

100S Reference ManualREFERENCE37100S uses positive and negative numbers to determine the position ofthe table and tool on each axis. The graphic below

Strona 36 - Electrical Specifications

100S Reference Manual38REFERENCEWarrantyACU-RITE Companies, Inc. Products and accessories are warrantedagainst defects in material and workmanship for

Strona 37 - Factory Default Settings

PRINTED IN USAACU-RITE COMPANIES, INC.ONE PRECISION WAYMASON INDUSTRIAL PARKJAMESTOWN, NY 14701www.acu-rite.com532821-20ACU-RITE Readout Systems are m

Strona 38

100S Reference ManualGENERAL2Packing List• Readout & installation instructions• Mounting arm • ENC 125 scale(s)- Cable mounting hardware- Scale mo

Strona 39

100S Reference ManualGENERAL3Installing the ReadoutFollow the readout installation instructions that are included with yourmounting arm bracket kit. T

Strona 40 - Conventions

100S Reference ManualGENERAL4Power UpPress the switch on the back of the readout to power up the system. Aseries of tests will check that the display,

Strona 41 - Warranty

100S Reference ManualSETUP5There are five parameters that you can define on your system:• Display resolution (diS)• Linear error compensation (LEC)• S

Strona 42 - CERTIFIED

6SETUP100S Reference ManualThe display resolution determines how detailed each scale’s positionwill be displayed on the readout. Use the setting that

Powiązane modele: 100S READOUTS for Milling

Komentarze do niniejszej Instrukcji

Brak uwag